BAC Cooling Tower
Cooling towers offer a proven and cost-effective solution for rejecting heat from condenser water and industrial processes. During operation, the condenser water or process water flows directly over the heat transfer surface of the cooling tower. As air is introduced into the tower, a fraction of ths water is evaporated, cooling the remaining water.
BAC Series 1500 Cooling Tower
MOST SERVICEABLE UNIT FOR TIGHT SPACES
-
The Series 1500 Cooling Tower is the best solution for applications requiring low maintenance and layout flexibility, as the single side air inlet design allows it to fit into tight spaces. It also has the lowest energy and maintenance costs. You can easily access all major components from the interior of the unit. Extreme Efficiency (XE) models further reduce the unit’s energy and operating costs.
Thermal Capacity: 92 - 747 tons1
Flow Rate: Up to 3,150 USGPM1
Crossflow // Axial Fan // Induced Draft
Benefits
ENERGY
Lowest Energy Usage
UP TO 40% MORE ENERGY EFFICIENT WITH XE MODELS
-
XE Models are at least two times more efficient than the minimum
-
requirements established in ASHRAE Standard 90.1
-
Helps contribute to Energy and Atmosphere LEED® Credits (EAc1)
-
Average payback of less than 2 years with BAC’s enhanced selections
-
which include user-defined life-cycle cost inputs based on energy savings
-
and minimum payback
MAINTENANCE
-
Lowest Maintenance Costs
-
26% LOWER ANNUAL MAINTENANCE COSTS*
-
Easy access to the cold water basin, hot water basin, and the drive system
-
with the crossflow design, large access doors, and an internal walkway
Fast inspection of the spray distribution system while the unit is in
-
operation
Increased ease of access with optional factory pre-assembled external
-
platforms and ladders
-
*Compared to counterflow cooling towers
RELIABILITY
-
Highest Reliability
-
DEPENDABLE BAC QUALITY
-
Enhanced longevity with a variety of durable unique materials of
-
construction including EVERTOUGH™ Construction, TriArmor® Corrosion
-
Protection System, thermosetting hybrid polymer, and stainless steel
-
options
Increased capacity control and redundancy with standard independent
-
fan motors
Reliable year-round operation with superior winter operating performance
Certified/complies with local codes including ASHRAE 90.1, CTI, IBC, and
-
OSHPD
LAYOUT
Increased Layout Flexibility
THE IDEAL REPLACEMENT UNIT FOR EXISTING BAC’S OR COMPETITORS’ EQUIPMENT
-
Fits in tight spaces with the single side air intake
Save on installation costs for replacement projects since it fits on existing
-
steel support, minimal piping changes, and has no enclosure
-
modifications because of the layout flexibility of the single air intake